Booster
Basai Root Vacuum Pump
A Basai Roots vacuum pump is a positive-displacement vacuum pump used to increase pumping speed and improve the pump-down performance of a vacuum system.
250 – 9000 m³/hPumping speed
6Models
12Key features
BRP-25 … BRP-900

Key features
Why the Root Vacuum Pump
- High pumping speed — suitable for large gas volumes.
- Oil-free pumping chamber — no oil enters the compression space.
- Non-contacting rotors — minimizes wear inside the pumping chamber.
- High reliability — suitable for continuous industrial operation.
- Low maintenance — mainly requires attention to bearings, seals and timing-gear lubrication.
- Wide capacity range — can be designed from small laboratory units to very large industrial boosters.
- High-temperature capability — suitable designs can handle elevated gas temperatures.
- Low contamination — useful for clean vacuum processes.
- Vertical or horizontal installation — depending on the pump design.
- Can operate with a backing pump — commonly used in combination with dry screw, rotary vane, liquid-ring or other backing pumps.
- Bypass/relief protection — commonly provided to prevent excessive differential pressure.
- Air- or water-cooled versions — depending on pump size and application.
Applications
Where it is used
Semiconductor, Electronics IndustryNuclear Energy Development ResearchAutomobile, Machinery, Aircraft IndustryScience & EngineeringHeavy Electrical EquipmentOptical IndustrySteel, metal industryChemistry, Pharmaceutical industryFood IndustryMetalworking IndustryEnergy connection
Technical data
6 models at a glance
Swipe sideways to see all models
| Parameters | Unit | BRP-25 | BRP-55 | BRP-110 | BRP-220 | BRP-440 | BRP-900 |
|---|---|---|---|---|---|---|---|
| Flow rate | m³ / h | 250 | 550 | 1100 | 2200 | 4400 | 9000 |
| Ultimate Vacuum | Pa | 5 × 10−2 | 5 × 10−2 | 5 × 10−2 | 5 × 10−2 | 5 × 10−2 | 5 × 10−2 |
| Motor Power | KW | 1.1 | 2.2 | 4 | 7.5 | 11 | 18.5 |
| Voltage | volt | 400 | 400 | 400 | 400 | 400 | 400 |
| Speed | rpm | 3000 | 3000 | 3000 | 3000 | 3000 | 3000 |
| Inlet | dia(mm) | 80 | 100 | 150 | 200 | 250 | 320 |
| Outlet | dia(mm) | 80 | 100 | 150 | 200 | 250 | 320 |
| Lubricant for the bearing chamber) vertical pumping action, approx. | L | 0.8 | 1.5 | 3.0 | 5.5 | 10 | 20 |
| Lubricant for the bearing chamber) horizontal pumping action, approx. | L | 0.7 | 1.3 | 2.7 | 5.2 | 9.5 | 19 |
| Lubricant of the shaft sealing ring housing | L | 1.0 | 1.5 | 3.0 | 5.5 | 10.5 | 21 |
| Type of Protection | IP | 55 | 55 | 55 | 55 | 55 | 55 |
| ATEX protection category | -- | Category 3i | Category 3i | Category 3i | Category 3i | Category 3i | Category 3i |
| Noise Level | dB(A) | ≤70 | ≤70 | ≤75 | ≤75 | ≤80 | ≤80 |
| Ambient Temperature Range | (°C) | 5 to 40 | 5 to 40 | 5 to 40 | 5 to 40 | 5 to 40 | 5 to 40 |
| Weight | Kg | 110 | 190 | 265 | 570 | 770 | 1350 |
Talk to a vacuum engineer