Single Claw Pumping Systems
Dry Single Claw Vacuum Pumping System
Single Claw Vacuum Pumping System Integrated with By-Chamber Condenser
- Ultimate vacuum
- 50 mbar abs
- Condenser
- By-chamber, 3 or 6 m²
- Wetted parts
- PTFE-coated
Key features
- Dry vacuum operation without sealing oil in the pumping chamber.
- PTFE-coated surfaces for improved chemical resistance.
- Integrated by-chamber condenser for solvent vapour condensation and recovery.
- Automatic solvent drainage with level-switch control.
- Suitable inlet filter selected according to the process solvent.
- Silencer available on request.
Typical applications
Pharmaceutical manufacturingChemical and speciality chemical processingSolvent recovery and distillationVacuum drying and evaporationProcess applications involving selected acidic solventsLow-boiling-point solvent vapour handling
Full specifications
Dry Claw Vacuum Pump
| Pump Type | Dry Single Claw Vacuum Pump |
|---|---|
| Ultimate Vacuum | 50 mbar (absolute) |
| Pump Body | Cast Iron |
| Claw Material | Stainless Steel (SS) |
| Wetted Parts | PTFE-coated, subject to process compatibility |
| Cleaning Facility | Self-cleaning arrangement using methanol and nitrogen (N₂), subject to approved cleaning procedure |
| Application | Solvent recovery and process vacuum applications |
| Recommended Process pH | Approximately pH 3, subject to chemical compatibility verification |
| Variable Frequency Drive (VFD) | Available on request |
By-Chamber Condenser
| Condenser Type | By-Chamber Condenser |
|---|---|
| Material of Construction (MOC) | SS 316 / SS 304 / Graphite, based on process compatibility |
| Condenser Surface Area | 3 m² / 6 m², as required by the customer |
| Drain System | Automatic solvent drain facility |
| Level Control | Integrated level switch |
| Solvent Drainage | Designed for solvent drainage without process interruption, subject to the final system configuration |
| Application | Condensation and recovery of solvent vapours |
| Suitability | Low-boiling-point solvents, subject to cooling conditions and condenser design |
All features and options
- Dry vacuum operation without sealing oil in the pumping chamber.
- PTFE-coated surfaces for improved chemical resistance.
- Integrated by-chamber condenser for solvent vapour condensation and recovery.
- Automatic solvent drainage with level-switch control.
- Suitable inlet filter selected according to the process solvent.
- Silencer available on request.
- Vacuum pump and by-chamber condenser mounted on a common base frame.
- 3 m² or 6 m² condenser surface area, selected according to process requirements.
- VFD control available on request.
- Designed for continuous process operation during solvent drainage, subject to the selected chamber and isolation arrangement.
To select your SC-VPS system, tell us
- Required vacuum pump capacity in m³/h.
- Solvent name and composition.
- Operating temperature and expected solvent vapour load.
- Required operating vacuum.
- Condenser cooling medium and inlet temperature.
- Required solvent recovery rate.
- Preferred condenser material of construction.
- Electrical supply and VFD requirements.
Engineering notes
The suitability of the pump, PTFE coating, stainless steel components, cast-iron body and condenser must be verified against the actual process chemicals, concentration, temperature and operating conditions. Process pH alone is insufficient to establish chemical compatibility.
Continuous drainage without process interruption depends on the final chamber arrangement, isolation valves and operating sequence. This functionality must be confirmed during detailed engineering.
Single Claw + Roots Vacuum Pumping System
Single Claw Vacuum Roots Pumping System Integrated with By-Chamber Condenser
- System vacuum
- 5 mbar abs (target)
- Roots booster
- 1,000 m³/h
- Condenser
- By-chamber, 3 or 6 m²
Key features
- Dry vacuum operation without sealing oil in the pumping chamber.
- Single claw pump combined with a Roots vacuum booster for improved pumping performance.
- PTFE-coated claw pump wetted surfaces for enhanced chemical resistance.
- Hastelloy-coated Roots booster wetted surfaces, subject to process compatibility.
- Integrated by-chamber condenser for solvent vapour condensation and recovery.
- Automatic solvent drainage with integrated level-switch control.
Typical applications
Pharmaceutical manufacturingChemical and speciality chemical industriesSolvent recovery and distillationVacuum drying and evaporationSelected acidic solvent applicationsLow-boiling-point solvent vapour handling
Full specifications
Dry Claw Vacuum Pump
| Pump Type | Dry Single Claw Vacuum Pump |
|---|---|
| Ultimate Vacuum | 50 mbar (absolute) |
| Pump Body | Cast Iron |
| Claw Material | Stainless Steel (SS) |
| Wetted Parts | PTFE-coated, subject to process compatibility |
| Cleaning Facility | Self-cleaning arrangement using methanol and nitrogen (N₂), subject to an approved cleaning procedure |
| Application | Solvent recovery and process vacuum applications |
| Recommended Process pH | Approximately pH 3, subject to chemical compatibility verification |
| Variable Frequency Drive (VFD) | Available on request |
Roots Vacuum Booster Pump
| Pump Type | Roots Vacuum Booster Pump |
|---|---|
| Pumping Speed | 1,000 m³/h |
| Pump Body | Cast Iron |
| Wetted Parts | Hastelloy-coated, subject to process compatibility |
| Ultimate Vacuum | Approximately one order of magnitude better than the single claw pump, subject to operating conditions |
| Target System Vacuum | 5 mbar (absolute) |
| Drive Arrangement | As per system design |
| Application | Increased pumping speed and improved vacuum performance |
System configuration: Dry single claw backing pump + Roots vacuum booster + by-chamber condenser.
By-Chamber Condenser
| Condenser Type | By-Chamber Condenser |
|---|---|
| Material of Construction (MOC) | SS 316 / SS 304 / Graphite, based on process compatibility |
| Condenser Surface Area | 3 m² / 6 m², as required by the customer |
| Drain System | Automatic solvent drain facility |
| Level Control | Integrated level switch |
| Solvent Drainage | Designed for solvent drainage without process interruption, subject to the final system configuration |
| Application | Condensation and recovery of solvent vapours |
| Suitability | Low-boiling-point solvents, subject to cooling conditions and condenser design |
All features and options
- Dry vacuum operation without sealing oil in the pumping chamber.
- Single claw pump combined with a Roots vacuum booster for improved pumping performance.
- PTFE-coated claw pump wetted surfaces for enhanced chemical resistance.
- Hastelloy-coated Roots booster wetted surfaces, subject to process compatibility.
- Integrated by-chamber condenser for solvent vapour condensation and recovery.
- Automatic solvent drainage with integrated level-switch control.
- Suitable inlet filter selected according to the process solvent.
- Silencer available on request.
- Complete system mounted on a common base frame.
- Condenser surface area options of 3 m² and 6 m².
- VFD control available on request.
- Designed for continuous operation during solvent drainage, subject to the final chamber and isolation arrangement.
To select your SC-RPS system, tell us
- Required process pumping speed in m³/h.
- Solvent name, composition and concentration.
- Operating temperature and expected vapour load.
- Required operating vacuum.
- Condenser cooling medium and inlet temperature.
- Required solvent recovery rate.
- Preferred condenser material of construction.
- Electrical supply and VFD requirements.
Engineering notes
The stated 5 mbar absolute system vacuum is a design target and must be confirmed against the actual operating conditions and system configuration.
The Roots booster requires suitable backing-pump capacity and pressure control. Its ultimate pressure cannot be established solely from the claw pump's 50 mbar rating.
Chemical compatibility must be verified using the actual process chemicals, concentration, temperature and exposure conditions. Process pH alone does not establish compatibility.
Continuous solvent drainage without process interruption depends on the chamber arrangement, isolation valves and operating sequence.
Technical recommendation: For the SC-RPS series, specify the 1,000 m³/h Roots booster capacity separately from the total system pumping speed. The combined system's actual pumping speed will depend on the backing pump, pressure, piping, condenser and vapour load.