    RED-Y ATEX Thermal Mass Flow Meters and  Controllers with IP67 & Ex Protection 
      Accurate & fast measurement/controlAnalog and digital interfaceIP67/NEMA6 and ATEX ratingOptions: Multigas (up to 10 gases), ProfibusMeasuring ranges from 25 mln/min up to 450 ln/min  (27 SCCM – 480 SLPM)Accuracy: ± 0.3% of full  scale + ± 0.5% of reading Turndown ratio: 1 : 100 Repeatability, ± 0.2% of  full scale  Power supply, 24 Vdc (18 –  30 Vdc), 15 Vdc on request Operating pressure, 0.2 – 11  bara (3 – 160 psia)  Body material, Stainless  steel 316L Output analog signal,  0-20 mA, 4-20 mA, 0-5 V, 1-5 V, 0-10 V, 2-10 V Output digital signal,  RS-485; Modbus RTU / option: Profibus IP Class IP67 Leak Rate < 1 x 10-6 mbar  l/s He Test Pressure 16 bara (240 psia) ATEX Cerification, II  3G nA IIC T4 Gc (Category 3/Zone 2) II 3D Ex tc IIIC T100°C Dc  (Category 3/Zone 22)  
  
    RED-Y COMPACT Battery Powered Digital Mass Flow  Meters with optional Needle Valve 
      AA battery powered device with touch displayMEMS sensor technologyCustomer-specific flow unitsUse as a meter, regulator or switchMeasuring ranges from 25 mln/min up to 450 ln/min  (27 SCCM – 480 SLPM)Turndown ratio  1:100 Accuracy, ± 1.0% of full  scale up to 50 ln/min (50 SLPM) Repeatability ± 0.5% of full  scale Response time Max. 300  msec  Operating pressure 0.2 – 11  bara (3 – 160 psia) Operating temperature 0 –  50°C (32 – 122°F) Body material, Anodized  aluminium, optional stainless steel electro polished Warm-up-Time, < 1 sec.  for full accuracy Display, ouch display  (128×64 px) with automatic position adjustment (position sensor) IP Class IP50 Leak Rate < 1 x 10-6 mbar  l/s He Test Pressure 16 bara (240 psia) No output signal. 
  
  RED-Y SMART High-precision Reliable and accurate Mass Flow Meters and Controllers (MFC) for Gases 
      High-precision measurementAnalog and digital interfaceSafe and fast controlOptions: Multigas (up to 10 gases), Profibus,  built-in displayMeasuring ranges from 25 mln/min up to 450 ln/min  (27 SCCM – 480 SLPM)Operating pressure 0.2 – 11  bar a (3 – 160 psia) Operating temperature 0 –  50°C (32 – 122°F) Accuracy: ± 0.3% of full  scale + ± 0.5% of reading Turndown ratio: 1 : 100 Repeatability ± 0.2% of full  scale Body material, Anodized  aluminum, optional stainless steel electro polished Warm-up-time, < 1 sec.  for full accuracy IP Class IP50 Leak Rate < 1 x 10-6 mbar  l/s He Test Pressure 16 bara (240 psia) Output signal analog, 0-20  mA, 4-20 mA, 0-5 V, 1-5 V, 0-10 V, 2-10 V Output signal digital, RS-485; Modbus RTU Option: Profibus DP-V0, DP-V1 / Profinet RT/EtherCAT 
  
    Q-FLOW Q-Flow is a modern VA-flowmeter for gases  built on the variable area principle. 
      Measuring tubes in 80mm and 140mm sizesMeasuring ranges from 0.06 ln/min up to 50 ln/min for Air @ 1013 mbar abs / 20°CMaximum pressure: 10 bar / Maximum temperature: 100°CThe bodies are available in aluminium. Sealing material FKM.Body in stainless steel 1.4305 and sealing materials EPDM or FFKM on request.
Operating temperature 0 100deg cStandard setup with valve at inletLeak Rate better than 1 x 10-5 mbar l/s He  
  
    M-FLOW  M-Flow  micro needle valves were developed for fine dosages of gases and  liquids. 
      Body  Material: Anodized aluminium or stainless steel Operating  temperature:  -40 °C to 100 °C Operating pressure: 40bar Leak rate  : < 1 x 10-5 mbar l/s He Digiturn with display with 100 divisions  
  
    GAS MIXING SYSTEM  Precise  measurement and stable regulation of behaviour are important if  the quality of gas mixtures is to be maintained at a high level. 
      The  control speed of less than 500 ms. Very  accurate and fast regulation High  repeatability Calibration  with the actual gas High  savings possible with mixed gases Independent  of temperature and pressure Easy  maintaining and service  
  
    ACCESSORIES  The PCU-10 permits the  operation of up to 10 flow meters or flow controllers of the  red-y smart series with predefined process recipes.  
      Display of the gas flow set value for each connected meter and controllerDisplay of the gas flow actual value for each connected meter and controllerSpecification and storage of set valuesStorage of up to 12 different gas mixtures as recipesTotal flow meter for each connected meter and controllerSpecification of minimum and maximum limit values with red alarm display on reaching the limitsGas mixer with up to 12 recipesDisplay of the instrument temperature of the connected meter and controllerMixed operation with Vögtlin and BHT devices possibleNo additional mains adaptor requiredControl of the connected meter and controller with a PC by means of PDM-U connection cableUse of the Vögtlin  get red-y  software on a PC for direct configuration of the meter and controller 
  
    Communication Cable  
       Communication cable PC/red-y galvanically separatedActive level converter USB/RS485Powered by power supply PSD 
  
    PSD – PLUG -Type Power Supply (1.8m) 
      Input: 100 – 240Vac, 50 – 60HzOutput: 24Vdc, approx. 0.5A (12W)connector with locking ring, dia. 2.1/5.5mm | 
 |  |  |  |